ENTTEC-LOGO

ENTTEC 73539 DIN PIXIE

ENTTEC-73539-DIN-PIXIE-FIG-1

Πληροφορίες προϊόντος

Προδιαγραφές:

  • Οδηγός δημιουργίας προσαρμοσμένου πρωτοκόλλου
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

Οδηγίες χρήσης προϊόντος

Εισαγωγή:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Απαιτήσεις εγκατάστασης:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

ΣΥΜΒΑΤΟ ΥΛΙΚΟ ΛΟΓΙΣΜΙΚΟ

Η δημιουργία προσαρμοσμένου πρωτοκόλλου εμφανίζεται στους ακόλουθους ελεγκτές pixel ENTTEC:

SKU Προϊόν Έκδοση υλικολογισμικού
73539 DIN PIXIE V2.0 ή παραπάνω
70067 PIXELATOR MINI V2.0 ή παραπάνω
70068 PIXELATOR MINI MK2 V1.0 ή παραπάνω
71521 OCTO MK2 V4.0 ή παραπάνω
71522 OCTO MK3 V1.0 ή παραπάνω

ΕΙΣΑΓΩΓΗ

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Αυτή η δυνατότητα επιτρέπει στους χρήστες να προσαρμόσουν την έντασηtagΧρονισμός με βάση τα υποστηριζόμενα πρωτόκολλα, εάν η μέθοδος μετάδοσης δεδομένων ταιριάζει με οποιοδήποτε από τα υποστηριζόμενα πρωτόκολλά μας.
  • Αυτό το έγγραφο παρέχει οδηγίες ρύθμισης για τη δημιουργία ενός προσαρμοσμένου πρωτοκόλλου pixel και την επαλήθευση των κριτηρίων.

ΑΠΑΙΤΗΣΕΙΣ ΡΥΘΜΙΣΗΣ

Για τη δημιουργία ενός προσαρμοσμένου πρωτοκόλλου απαιτούνται τα ακόλουθα:

  1. Φύλλο δεδομένων: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Συσκευή: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

ΟΔΗΓΟΣ ΔΗΜΙΟΥΡΓΙΑΣ ΠΡΟΣΑΡΜΟΣΜΕΝΟΥ ΠΡΩΤΟΚΟΛΛΟΥ

Αυτή η δυνατότητα επιτρέπει στους χρήστες να προσαρμόσουν τον όγκο δεδομένωνtage timing to meet specific protocol needs. To create a custom protocol:

  1. Επαληθεύστε το φύλλο δεδομένων για το συμβατό πρωτόκολλο pixel.
  2. Μεταβείτε στη διεπαφή χρήστη της συσκευής για να ενεργοποιήσετε τη δυνατότητα προσαρμοσμένου πρωτοκόλλου.
  3. Προσαρμόστε τον όγκο δεδομένων του φωτιστικού pixeltage χρονομέτρηση μέσω του web διεπαφή σύμφωνα με το φύλλο δεδομένων του κατασκευαστή.

Βήμα 1: Επαληθεύστε το φύλλο δεδομένων για το συμβατό πρωτόκολλο

  1. Επαληθεύστε τη μέθοδο μετάδοσης δεδομένων του πρωτοκόλλου που θέλετε από το φύλλο δεδομένων.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Η πιο κοινή μέθοδος μεταδίδει δεδομένα χωρίς πρόσθετα bit (π.χ. D1-D2-D3…Dn).
        Example: Πληροφορίες που λαμβάνονται από το φύλλο δεδομένων του WB2812B

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Ορισμένα πρωτόκολλα, όπως το TM1814, περιλαμβάνουν πρόσθετα δεδομένα στο μπροστινό μέρος (π.χ. C1-C2-D1-D2…Dn).
        Example: Πληροφορίες που συλλέγονται από το φύλλο δεδομένων του TM1814

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Ορίστε το πρωτόκολλο αντιστοίχισης που υποστηρίζεται από τη συσκευή (ή επιλέξτε από τα παραπάνω π.χample) that shares the same data transmission method as your desired pixel protocol.
  3. Προχωρήστε στο Βήμα 2 για περαιτέρω διαμόρφωση.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web διεπαφή
    1. Το Google Chrome προτείνεται ως το web browser to access the OCTO/PIXELATOR MINI’s web διεπαφή.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webιστότοπο www.enttec.com για λήψη της εφαρμογής.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Μεταβείτε στην έξοδο όπου είναι συνδεδεμένο το επιθυμητό εξάρτημα pixel. Επιλέξτε ένα πρωτόκολλο pixel από την αναπτυσσόμενη λίστα που μοιράζεται την ίδια μέθοδο μετάδοσης που επαληθεύτηκε στο Βήμα 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Ενεργοποιήστε το πλαίσιο επιλογής «Προσαρμοσμένο» για πρόσβαση στα δεδομένα τόμtage ρύθμιση χρονισμού. Καταργήστε την επιλογή για να απενεργοποιήσετε το προσαρμοσμένο πρωτόκολλο.

    ENTTEC-73539-DIN-PIXIE-FIG-6

Για DIN PIXIE

  1. Συνδέστε το DIN PIXIE σε υπολογιστή χρησιμοποιώντας USB Type-B.
  2. Εκκινήστε το λογισμικό EMU.
  3. Σάρωση για τη συσκευή και κάντε κλικ στο Conf του ανακαλυφθέντος DIN PIXIE.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Βήμα 3: Ορισμός προσαρμοσμένου τόμουtage timing

  1. Ταίριαξε με τον τόμtagχρονομέτρηση στο φύλλο δεδομένων του πρωτοκόλλου που επιθυμείτε. Το προσαρμοσμένο πρωτόκολλο απαιτεί 4 εισόδους για την ολοκλήρωση του τόμου δεδομένωνtage ρύθμιση χρονισμού:
    Τομtage Timing Definition
    High Time Bit 0 (T0H) Ο τόμοςtage υψηλός χρόνος που απαιτείται για τον κωδικό 0.
    High Time Bit 1 (T1H) Ο τόμοςtage υψηλός χρόνος που απαιτείται για τον κωδικό 1.
    Overall Bit Time: Ο συνολικός τόμtage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Επαναφορά χρόνου Ο συνολικός τόμtage χαμηλός χρόνος που απαιτείται για την επαναφορά της μετάδοσης δεδομένων μεταξύ κάθε παρτίδας δεδομένων.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Datasheet – Data voltage πληροφορίες χρονισμού Π.χample
    Από το φύλλο δεδομένων του WB2818B
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltagε εύρος χρονισμού.
    • Συμπληρώστε τον τόμtagεύρος χρονισμού στο προσαρμοσμένο πεδίο στις Ρυθμίσεις εξόδου.

      ENTTEC-73539-DIN-PIXIE-FIG-10

ΣΠΟΥΔΑΙΟΣ

  • ENTTEC recommends taking the median value of the range for the start.
  • Ο χρήστης θα πρέπει να ΑΠΟΘΗΚΕΥΕΙ τις ρυθμίσεις για να τεθεί σε ισχύ η τροποποιημένη τιμή.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

ΣΥΝΑΨΗ

  • Αυτός ο οδηγός παρουσίασε πώς να ρυθμίσετε ένα προσαρμοσμένο πρωτόκολλο για τις κατάλληλες συσκευές ENTTEC και παρείχε τεχνικές γνώσεις σχετικά με την επαλήθευση του φύλλου δεδομένων των επιθυμητών εξαρτημάτων pixel.
  • Ακολουθώντας αυτά τα βήματα, οι χρήστες μπορούν να δημιουργήσουν ένα προσαρμοσμένο πρωτόκολλο pixel που δεν βρίσκεται στην αναπτυσσόμενη λίστα χωρίς να περιμένουν την τεχνική υποστήριξη ή μια νέα έκδοση υλικολογισμικού. Εάν έχετε ερωτήσεις ή δυσκολεύεστε να βρείτε τις σωστές πληροφορίες, επικοινωνήστε με τη φιλική ομάδα υποστήριξης στα τοπικά γραφεία.

FAQ

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web πρόγραμμα περιήγησης.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Έγγραφα / Πόροι

ENTTEC 73539 DIN PIXIE [pdf] Εγχειρίδιο οδηγιών
DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Αναφορές

Αφήστε ένα σχόλιο

Η διεύθυνση email σας δεν θα δημοσιευτεί. Τα υποχρεωτικά πεδία επισημαίνονται *