This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.
2. Πληροφορίες Ασφάλειας
Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.
- Ηλεκτρική ασφάλεια: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
- Χειρισμός ψυκτικού μέσου: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
- Εγκατάσταση: Installation must be performed by a licensed HVAC professional.
- Εξοπλισμός Ατομικής Προστασίας: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.
3. Βασικά Χαρακτηριστικά
- Τεχνολογία μετατροπέα: Provides precise temperature control, reduced energy consumption, and quieter operation.
- Υψηλή απόδοση: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
- Ευρύ εύρος λειτουργίας: Reliable performance from -13°F to 122°F.
- Αθόρυβη λειτουργία: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
- Ανθεκτικά συστατικά: Rotary compressor, aluminum coil, and fiberglass-free insulation.
- Οικολογικό ψυκτικό μέσο: Utilizes R-454B refrigerant.
- Ευέλικτη εγκατάσταση: Supports horizontal and vertical air handler installation.
- Έξυπνα χειριστήρια: Compatible with wired controllers, WiFi, and third-party thermostats.
- Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.
4. Components Overview
The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:
- Outdoor Condensing Unit (Heat Pump)
- Μονάδα χειρισμού εσωτερικού αέρα
- 10kW Back-up Heat Kit
- 30' Line Set
- Gauge Electrical Whip
- 60A Non-Fused Disconnect Switch
- Θερμοστάτης WiFi
- Προστασία από υπερτάσεις
- CPS Charging Adapter
- Μανίκι τοίχου

Εικόνα 1: Υπερview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.
5. Ρύθμιση και εγκατάσταση
Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.
5.1 Έλεγχοι προεγκατάστασης
- Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
- Εξασφαλίστε επαρκή χώρο τόσο για τις εσωτερικές όσο και για τις εξωτερικές μονάδες, επιτρέποντας την κατάλληλη ροή αέρα και την πρόσβαση στη συντήρηση.
- Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.
5.2 Air Handler Installation
The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Εικόνα 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.
5.3 Τοποθέτηση εξωτερικής μονάδας
Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Εικόνα 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.
6. Οδηγίες λειτουργίας
Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.
6.1 Βασικές Λειτουργίες
- Λειτουργία ψύξης: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
- Λειτουργία θέρμανσης: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
- Λειτουργία ανεμιστήρα: Κυκλοφορεί τον αέρα χωρίς θέρμανση ή ψύξη.
- Αυτόματη λειτουργία: Αυτόματη εναλλαγή μεταξύ θέρμανσης και ψύξης για τη διατήρηση της καθορισμένης θερμοκρασίας.

Εικόνα 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

Εικόνα 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.
6.2 Έξυπνα χειριστήρια
The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

Εικόνα 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.
7. Συντήρηση
Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.
- Αντικατάσταση φίλτρου αέρα: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
- Καθαρισμός εξωτερικής μονάδας: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
- Σύστημα αποχέτευσης: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
- Επαγγελματικός έλεγχος: Schedule annual inspections and maintenance by a qualified HVAC technician.
8. Αντιμετώπιση Προβλημάτων
This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.
- Χωρίς ισχύ: Check circuit breakers and ensure the disconnect switch is in the ON position.
- Ανεπαρκής θέρμανση/ψύξη: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
- Ασυνήθιστοι θόρυβοι: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
- Διαρροές νερού: Check condensate drain line for blockages.
9. Προδιαγραφές

Εικόνα 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Εικόνα 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Εικόνα 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).
| Χαρακτηριστικό | Λεπτομέρεια |
|---|---|
| Ψυκτική ικανότητα | 31,000 BTU/ώρα |
| Ικανότητα θέρμανσης | 30,000 BTU/hr (at 47°F) |
| Βαθμολογία SEER2 | 18.8 |
| Βαθμολογία HSPF2 | 9.7 |
| Τύπος ψυκτικού | R-454B |
| Τροφοδοτικό Εσωτερικής Μονάδας | 115/208/230V, 60Hz, 1Ph |
| Τροφοδοτικό εξωτερικής μονάδας | 208/230V, 60Hz, 1Ph |
| Μέγιστο μήκος σωληνώσεων | 164 πόδια (50 μέτρα) |
| Max Height Difference | 82 πόδια (25 μέτρα) |
| Indoor Unit Dimensions (W × D × H) | 21.02" × 21.02" × 49.02" |
| Outdoor Unit Dimensions (W × D × H) | 37.24" × 16.14" × 31.89" |
| Καθαρό βάρος εσωτερικής μονάδας | 128.97 λίβρες |
| Καθαρό βάρος εξωτερικής μονάδας | 164.02 λίβρες |
10. Εγγύηση και υποστήριξη
ACiQ offers a comprehensive warranty for this heat pump system:
- Εγγύηση ανταλλακτικών: 7 χρόνια
- Εγγύηση συμπιεστή: 12 χρόνια
These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webτοποθεσία.