1. Εισαγωγή
The Altronix R2416300UL is a rack mount power supply designed to provide 24VAC or 28VAC power for various applications, particularly commercial CCTV equipment. This unit features 16 individually fused outputs, ensuring reliable power distribution and protection. It is housed in a durable steel enclosure and includes a line cord, spare fuse, removable terminal blocks, and mounting brackets for convenient installation.
2. Σημαντικές πληροφορίες για την ασφάλεια
Please read these safety instructions carefully before installing or operating the Altronix R2416300UL power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.
- Κίνδυνος ηλεκτροπληξίας: Do not open the unit. Refer all servicing to qualified service personnel.
- Αντικατάσταση ασφαλειών: For continued protection against fire, replace all fuses with the same type and rating (3.5A, 250V).
- Περιβαλλοντικές Συνθήκες: Do not expose the unit to rain or moisture. Install in a dry, indoor location.
- Αερισμός: Βεβαιωθείτε ότι υπάρχει επαρκής αερισμός γύρω από τη μονάδα για να αποτρέψετε την υπερθέρμανση.
- Γείωση: Βεβαιωθείτε ότι η μονάδα είναι σωστά γειωμένη σύμφωνα με τους τοπικούς ηλεκτρικούς κώδικες.
- Πηγή ενέργειας: Connect the unit only to a 115VAC, 60Hz power source.

Εικόνα 1: Εμπρός view of the Altronix R2416300UL Rack Mount Power Supply. This image shows the black steel enclosure with the Altronix logo and 16 green LED indicators for each output. A caution label for electric shock is visible on the right.
3. Ρύθμιση και εγκατάσταση
3.1. Αποσυσκευασία
Carefully remove the power supply from its packaging. Verify that all components are present: the R2416300UL unit, line cord, spare fuse, removable terminal blocks, and mounting brackets.
3.2. Τοποθέτηση
The R2416300UL is designed for rack mounting. Use the provided mounting brackets to secure the unit into a standard 19-inch equipment rack. Ensure the rack is stable and provides adequate support for the unit's weight (approximately 17.2 pounds).
3.3. Σύνδεση τροφοδοσίας εισόδου
- Βεβαιωθείτε ότι ο διακόπτης λειτουργίας στο πίσω μέρος της μονάδας βρίσκεται στη θέση "OFF".
- Connect the supplied line cord to the AC input receptacle on the rear of the power supply.
- Plug the other end of the line cord into a grounded 115VAC, 60Hz power outlet.

Εικόνα 2: Πίσω view of the Altronix R2416300UL Rack Mount Power Supply. This image displays the power switch, AC input, and the array of 16 output terminal blocks. The product label with specifications is also visible.
3.4. Συνδέσεις εξόδου
The R2416300UL provides 16 individually fused 24VAC or 28VAC outputs. Each output is equipped with a removable terminal block for easy wiring.
- Identify the desired output terminal block (labeled 1 through 16).
- Connect your device's power input wires to the corresponding terminals on the removable block. Ensure correct polarity if applicable to your device.
- Securely insert the wired terminal block into its receptacle on the power supply.
- Repeat for all devices requiring power.

Figure 3: Close-up of the rear product label and output terminal blocks. This image provides a detailed view of the product specifications, safety warnings, and the green removable terminal blocks for connecting output devices.
4. Οδηγίες λειτουργίας
4.1. Ενεργοποίηση/Απενεργοποίηση
- To power on the unit, flip the power switch on the rear panel to the "ON" position.
- To power off the unit, flip the power switch on the rear panel to the "OFF" position.
4.2. Output Indicators
The front panel of the R2416300UL features 16 green LED indicators, one for each output. A lit green LED indicates that the corresponding output is receiving power and the fuse is intact.

Figure 4: Close-up of the front panel showing the 16 green LED indicators. Each LED corresponds to an individual fused output, providing a visual status of power delivery.
5. Συντήρηση
5.1. Γενική Φροντίδα
- Διατηρείτε τη μονάδα καθαρή και απαλλαγμένη από σκόνη. Χρησιμοποιήστε ένα στεγνό, μαλακό πανί για τον καθαρισμό.
- Βεβαιωθείτε ότι τα ανοίγματα εξαερισμού δεν εμποδίζονται.
5.2. Αντικατάσταση ασφαλειών
If an output LED is off, the corresponding fuse may be blown. To replace a fuse:
- Απενεργοποιώ: Disconnect the unit from the main power supply by unplugging the line cord.
- Προσδιορίστε την καμένη ασφάλεια: Locate the fuse holder for the affected output on the rear panel.
- Remove Fuse: Αφαιρέστε προσεκτικά την καμένη ασφάλεια.
- Install New Fuse: Replace it with a new fuse of the exact same type and rating: 3.5A, 250V. Using an incorrect fuse can cause damage or fire.
- Επαναφορά ισχύος: Reconnect the unit to the main power supply and turn it on. Verify the output LED illuminates.
6. Αντιμετώπιση Προβλημάτων
| Πρόβλημα | Πιθανή αιτία | Διάλυμα |
|---|---|---|
| No power to the unit (no LEDs lit). |
|
|
| One or more output LEDs are off. |
|
|
| Unit powers on, but connected devices do not function. |
|
|
7. Προδιαγραφές
| Χαρακτηριστικό | Λεπτομέρεια |
|---|---|
| Μάρκα | Altronix |
| Αριθμός μοντέλου | R2416300UL |
| Είσοδος Voltage | 115VAC (Minimum 110V, Maximum 115V) |
| Συχνότητα εισόδου | 60 Hz |
| Έξοδος Τόμοςtage | 24VAC ή 28VAC |
| Output Current (24VAC) | 12.5A |
| Output Current (28VAC) | 10A |
| Number of Fused Outputs | 16 |
| Τύπος/Ονομαστική τιμή ασφάλειας | 3.5A, 250V |
| Form Factor | Rack Mount |
| Υλικό περιβλήματος | Ατσάλι |
| Φινίρισμα | Μαύρος |
| Διαστάσεις προϊόντος (Μ x Π x Υ) | 19.13 x 8.5 x 3.27 ίντσες |
| Βάρος αντικειμένου | 17.2 λίρες |
| Πρότυπα | UL 2044 Commercial CCTV, CUL, CE |
| Μέθοδος Ψύξης | Αέρας |
8. Εγγύηση και υποστήριξη
8.1. Πληροφορίες εγγύησης
Altronix products are typically backed by a limited lifetime warranty. For specific warranty terms and conditions applicable to your R2416300UL unit, please refer to the official Altronix webιστότοπο ή επικοινωνήστε απευθείας με την εξυπηρέτηση πελατών. Κρατήστε την απόδειξη αγοράς σας ως απόδειξη αγοράς.
8.2. Τεχνική Υποστήριξη
For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact Altronix technical support. You can find their contact information on the official Altronix webιστοσελίδα (www.altronix.com).